LYNN Publishers
Journal of Sustainable Development StudiesISSN 2960-3676 · Open Access

Archive › Vol 11, No 1 (2018) › Articles

Evaluation of the Indoor Thermal Comfort of Selected Residents in Ibadan, Nigeria

Adewale Oluseyi Adunola

Vol 11, No 1 (2018) · Published 21 February 2018

Download PDF

Abstract

This study evaluated the thermal responses of residents of naturally ventilated buildings in Ibadan, Nigeria. 93 buildings were systematically selected in the Olubadan estate, Ibadan and questionnaire was administered to an adult resident in each of the selected buildings. Respondents assessed their respective living rooms at different periods of the day using a seven-point thermal comfort scale. The Mean Votes for the different periods of the day were: morning - cool, afternoon "“warm, evening -cool and night-cool. The indoor thermal comfort level of the naturally ventilated buildings was acceptable to the residents. The results of linear regression showed that the thermal response (y) had strong linear relationship with air temperature (x) with these equations: y = 9.7-0.24x for morning (with R2= 0.025 and p= 0.132) and

y= -7.1+0.37x for afternoon (with R2 =0.047 and p= 0.038). The study concluded that the acceptable limits of comfort expressed by the residents were between 22.60C and 25.60C. The value of the neutral temperature was determined to be 24.60C.

 

How to Cite

Adewale Oluseyi Adunola. Evaluation of the Indoor Thermal Comfort of Selected Residents in Ibadan, Nigeria. Journal of Sustainable Development Studies, Vol 11, No 1 (2018).

This article is published open access.